Accordion-folded underlay 2mm 10,5 m2

Characteristics

Accordion-folded underlay 2mm 10,5 m2

    Sub-floor levelling 1 mm

    Waterproofing

    Thermal resistance 0,06 m2K/W

    Sound insulation 19 dB

    Compression resistance 10t/m2

    Easy installatoin and quick laying

    View all specifications Price request
Density kg/m3: 35 ± 7
Color: Yellow
Size: 1050х10000 mm
Fold width: 0,5 m
Quantity/pack, m2: 10,5
Number in the box: 9
Quantity/box,m2: 94,5
Material: XPS
Flooring: Laminate / parquet board
Supplied in: Accordion-folded
Thickness, mm: 2
Key characteristics:
    Load resistance / Quick installation /

General features: Quick installation and consumables ecomony. Accordion-folder underlay sheets have been already fastened together. High load capacity.
Antibacterial properties: The underlayment possesses bactericidal and fungicidal properties, and specifically effective against: Aspergillus brasiliensis (ATCC 9642), Penicillium funiculosum (ATCC 11797), Chaetomium globosum (ATCC 6205), Trichoderma virens (ATCC 9645), Aureobasidium Pullulans (ATCC 15233)» (According to the studies conducted by Intertek Testing Services Taiwan Ltd.)
Description: THE RECOMMENDATIONS OF THE MANUFACTUREROF THE FLOOR COVERING ARE A PRIORITY WHEN CHOOSING A UNDERLAY FOR LAMINATE AND LVT.SPC.WPC FLOOR COVERING It's necessary to check the match between the characteristics indicated on the Label of the product with the recommendations of the manufacturer of the flooring with which the product is supposed to be used before purchasing and laying. In case of mismatch of the specified characteristics, no claims will be accepted. The flooring manufacturer recommendations should always be followed when laying the floating floors (parquet flooring, laminate flooring). Unless contradictory to the flooring manufacturer data, the following guidelines shall be followed for the underlay: 1. The surface of the concrete floor on which the underlay will be laid must be dry. 2. Underlay without the vapor sealing layer shall be laid over the vapor sealing film spread on the concrete. 3. Starting from the comer of the room, spread the underlay sheet across the direction in which the laminate flooring or parquet flooring will be further laid, proceed gradually on the entire surface. 4. Leave a gap of approximately 5 mm near the walls along the room perimeter. Use metallized adhesive tape Solid Aqua Stop for efficient and tight attachment of sheets to each other. Attention! Do not glue or attach the underlay sheets to the floor or walls! Do not install the underlay in several layers.

Packaging

Model in the interior