Sheet underlay 3 mm
CharacteristicsSheet underlay 3 mm
Sub-floor levelling 2 mm
Waterproofing
Thermal resistance 0,09 m2K/W
Sound insulation 20 dB
Compression resistance 8t/m2
Density kg/m3: 28 ± 7
Color: Green
Size: 500х1000
Quantity/pack, m2: 5
Number in the box: 18
Quantity/box,m2: 90
Material: XPS
Flooring: Laminate / parquet board
Supplied in: Sheets
Thickness, mm: 3
Key characteristics:
Antibacterial properties: The underlayment possesses bactericidal and fungicidal properties, and specifically effective against: Aspergillus brasiliensis (ATCC 9642), Penicillium funiculosum (ATCC 11797), Chaetomium globosum (ATCC 6205), Trichoderma virens (ATCC 9645), Aureobasidium Pullulans (ATCC 15233)» (According to the studies conducted by Intertek Testing Services Taiwan Ltd.)
Description: THE RECOMMENDATIONS OF THE MANUFACTUREROF THE FLOOR COVERING ARE A PRIORITY WHEN CHOOSING A UNDERLAY FOR LAMINATE AND LVT.SPC.WPC FLOOR COVERING Before acquisition and laying, it is needed to check the correspondence of the characteristics specified on the label of the present kind of the underlay with the recommendations of the manufacturer of the flooring with which it is intended to be used. No claims will be accepted in case of non-correspondence with the specified characteristics. This kind of underlay SHALL NOT BE APPLIED in the warm water underfloor heating and electric underfloor heating systems! In all cases, the recommendations of the manufacturer of the seLected Flooring should be strictly observed, and if there are no other instructions, the following instructions are relevant For the underLay: 1.The subfloor on which the underlay is to be laid must be clean, dry, solid, Free From defects, and without the height differences greater than the leveling capacity oF the underlay (see pictogram). 2. When applying on the cold mineral subfloor or subfloor structures it is recommended to apply the laminated underlay with a special vapor-barrier layer or apply the underlay on the water- and vapor-barrier film SOLID BASE+. 3. Starting From a room corner lay the underlay sheets tightly to each other with a haLF-sheet offset (Like brickwork) perpendicularly to the direction in which the Laminate panels are pLanned to be Laid, consistently over the entire area of the room. 4. Cut the underlay along the perimeter of the room with a cutter knife leaving the expansion clearance of around 3-5 mm along the walls. 5. Apply the adhesive tape aLong the whole Length of the joints. We recommend to use the metallized adhesive tape SoLid Aqua Stop to achieve effective and waterproof binding of the sheets. Warning! DO NOT attach and DO NOT glue the underlay to the Floor or to the walls (neither with adhesive tape, not with screws or staples). DO NOT lay the underlay in several layers!
Color: Green
Size: 500х1000
Quantity/pack, m2: 5
Number in the box: 18
Quantity/box,m2: 90
Material: XPS
Flooring: Laminate / parquet board
Supplied in: Sheets
Thickness, mm: 3
Key characteristics:
- Subfloor leveling /
Antibacterial properties: The underlayment possesses bactericidal and fungicidal properties, and specifically effective against: Aspergillus brasiliensis (ATCC 9642), Penicillium funiculosum (ATCC 11797), Chaetomium globosum (ATCC 6205), Trichoderma virens (ATCC 9645), Aureobasidium Pullulans (ATCC 15233)» (According to the studies conducted by Intertek Testing Services Taiwan Ltd.)
Description: THE RECOMMENDATIONS OF THE MANUFACTUREROF THE FLOOR COVERING ARE A PRIORITY WHEN CHOOSING A UNDERLAY FOR LAMINATE AND LVT.SPC.WPC FLOOR COVERING Before acquisition and laying, it is needed to check the correspondence of the characteristics specified on the label of the present kind of the underlay with the recommendations of the manufacturer of the flooring with which it is intended to be used. No claims will be accepted in case of non-correspondence with the specified characteristics. This kind of underlay SHALL NOT BE APPLIED in the warm water underfloor heating and electric underfloor heating systems! In all cases, the recommendations of the manufacturer of the seLected Flooring should be strictly observed, and if there are no other instructions, the following instructions are relevant For the underLay: 1.The subfloor on which the underlay is to be laid must be clean, dry, solid, Free From defects, and without the height differences greater than the leveling capacity oF the underlay (see pictogram). 2. When applying on the cold mineral subfloor or subfloor structures it is recommended to apply the laminated underlay with a special vapor-barrier layer or apply the underlay on the water- and vapor-barrier film SOLID BASE+. 3. Starting From a room corner lay the underlay sheets tightly to each other with a haLF-sheet offset (Like brickwork) perpendicularly to the direction in which the Laminate panels are pLanned to be Laid, consistently over the entire area of the room. 4. Cut the underlay along the perimeter of the room with a cutter knife leaving the expansion clearance of around 3-5 mm along the walls. 5. Apply the adhesive tape aLong the whole Length of the joints. We recommend to use the metallized adhesive tape SoLid Aqua Stop to achieve effective and waterproof binding of the sheets. Warning! DO NOT attach and DO NOT glue the underlay to the Floor or to the walls (neither with adhesive tape, not with screws or staples). DO NOT lay the underlay in several layers!
Individual packaging
Size underlay